Показать сокращенную информацию

dc.contributor.author Tummon, F.
dc.contributor.author Bruffaerts, N.
dc.contributor.author Celenk, S.
dc.contributor.author Choël, M.
dc.contributor.author Clot, B.
dc.contributor.author Crouzy, B.
dc.contributor.author Galán, C.
dc.contributor.author Gilge, S.
dc.contributor.author Hajkova, L.
dc.contributor.author Mokin, V.
dc.contributor.author O'Connor, D.
dc.contributor.author Rodinkova, V.
dc.contributor.author Sauliene, I.
dc.contributor.author Sikoparija, B.
dc.contributor.author Sofiev, M.
dc.contributor.author Sozinova, O.
dc.contributor.author Tesendic, D.
dc.contributor.author Vasilatou, K.
dc.date.accessioned 2025-03-25T17:27:04Z
dc.date.available 2025-03-25T17:27:04Z
dc.date.issued 2024
dc.identifier.citation Tummon F. Towards standardisation of automatic pollen and fungal spore monitoring: best practises and guidelines / F. Tummon, N. Bruffaerts, S. Celenk, M. Choël, B. Clot, B. Crouzy, C. Galán, S. Gilge, L. Hajkova, V. Mokin, D. O'Connor, V. Rodinkova, I. Sauliene, B. Sikoparija, M. Sofiev, O. Sozinova, D. Tesendic, K. Vasilatou // Aerobiologia. – 2024. – Volume 40. – Р. 39-55 uk_UA
dc.identifier.other WOS:000850738900001
dc.identifier.other http://dx.doi.org/10.1007/s10453-022-09755-6
dc.identifier.uri https://dspace.vnmu.edu.ua/123456789/9077
dc.description.abstract Standards for manual pollen and fungal spore monitoring have been established based on several decades of experience, tests, and research. New technological and methodological advancements have led to the development of a range of different automatic instruments for which no standard yet exist. This paper aims to provide an overview of aspects that need to be considered for automatic pollen and fungal spore monitoring, including a set of guidelines and recommendations. It covers issues relevant to developing an automatic monitoring network, from the instrument design and calibration through algorithm development to site selection criteria. Despite no official standard yet existing, it is essential that all aspects of the measurement chain are carried out in a manner that is as standardised as possible to ensure high-quality data and information can be provided to end-users. uk_UA
dc.language.iso en uk_UA
dc.subject Pollen uk_UA
dc.subject Fungal spores uk_UA
dc.subject Automatic monitoring uk_UA
dc.subject Standards uk_UA
dc.subject Protocols uk_UA
dc.subject Guidelines uk_UA
dc.title Towards standardisation of automatic pollen and fungal spore monitoring: best practises and guidelines uk_UA
dc.type Article uk_UA


Файлы в этом документе

Данный элемент включен в следующие коллекции

Показать сокращенную информацию

Поиск в DSpace


Просмотр

Моя учетная запись

Статистика