Repository of National Pirogov Memorial Medical University, Vinnytsia

The photonic device for integrated evaluation of collateral circulation of lower extremities in patients with local hypertensive-ischemic pain syndrome

Show simple item record

dc.contributor.author Pavlov, V. S. en
dc.contributor.author Bezsmernyi, Yu. O. en
dc.contributor.author Zlepko, S. M. en
dc.contributor.author Bezsmertna, H. V. en
dc.date.accessioned 2021-01-12T19:48:19Z
dc.date.available 2021-01-12T19:48:19Z
dc.date.issued 2017
dc.identifier.citation The photonic device for integrated evaluation of collateral circulation of lower extremities in patients with local hypertensive-ischemic pain syndrome / V. S. Pavlov, Yu. O. Bezsmernyi, S. M. Zlepko, H. V. Bezsmertna // Proc. of SPIE, Infrared Sensors, Devices and Applications VII. – 2017, August 30. – Vol. 10404, 1040409-10. en
dc.identifier.other doi: 10.1117/12.2272324
dc.identifier.uri https://dspace.vnmu.edu.ua/123456789/5041
dc.description Event: SPIE Optical Engineering + Applications, 2017, San Diego, California, United States. en
dc.description.abstract The given paper analyzes principles of interaction and analysis of the reflected optical radiation from biotissue in the process of assessment of regional hemodynamics state in patients with local hypertensive- ischemic pain syndrome of amputation stumps of lower extremities, applying the method of photoplethysmography. The purpose is the evaluation of Laser photoplethysmography (LPPG) diagnostic value in examination of patients with chronic ischemia of lower extremities. Photonic device is developed to determine the level of the peripheral blood circulation, which determines the basic parameters of peripheral blood circulation and saturation level. Device consists of two sensors: infrared sensor, which contains the infrared laser radiation source and photodetector, and red sensor, which contains the red radiation source and photodetector. LPPG method allows to determined pulsatility of blood flow in different areas of the foot and lower leg, the degree of compensation and conservation perspectives limb. Surgical treatment of local hypertensive – ischemic pain syndrome of amputation stumps of lower extremities by means of semiclosed fasciotomy in combination with revasculating osteotrepanation enabled to improve considerably regional hemodynamics in the tissues of the stump and decrease pain and hypostatic disorders. en
dc.language.iso en en
dc.subject sensors optical en
dc.subject photoplethysmography en
dc.subject level of blood filling en
dc.subject biotissue en
dc.subject signal biomedical en
dc.subject syndrome local hypertensive-ischemic pain en
dc.subject stumps en
dc.title The photonic device for integrated evaluation of collateral circulation of lower extremities in patients with local hypertensive-ischemic pain syndrome en
dc.type Thesis en