Показати скорочений опис матеріалу
dc.contributor.author | Goray, M. A. | en |
dc.contributor.author | Gadzhula, N. G. | en |
dc.contributor.author | Muntian, O. V. | en |
dc.contributor.author | Cherepakha, O. L. | en |
dc.contributor.author | Kurdysh, L. F. | en |
dc.date.accessioned | 2023-03-17T09:27:17Z | |
dc.date.available | 2023-03-17T09:27:17Z | |
dc.date.issued | 2020 | |
dc.identifier.citation | Comparative quality assessment of root canal preparation with different systems of endodontic instruments / M. A. Goray, N. G. Gadzhula, O. V. Muntian [et al.] // Wiadomości Lekarskie. – 2020. – Vol. 73, issue 6. – P. 1145–1148. | en |
dc.identifier.uri | https://dspace.vnmu.edu.ua/123456789/6102 | |
dc.description.abstract | The aim: To compare the quality of root canal system preparation with the use of manual K-files, machine Protaper Universal and Silk les by in vitro studies. Materials and methods: Root canals preparation in 45 extracted premolars was performed in three groups with 15 teeth in each with K- files, Protaper Universal and Silk les. Transverse sections of the dental root were prepared. Histologically were assessed: amount of sawdust and predentin remaining, the purity degree of root canal walls. Results: When calculating the sawdust amount at the distance of 3 mm from an apex, a high degree of contamination was observed in the manual K- file group: 53.3% versus 33.3% in the Protaper Universal group and against 20.0% in the Silk file group. The amount of predentin after root canal treatment with manual files reached 25-30%. At the distance of 5 mm from the apex the root canals with high and medium purity degree were detected in 86.7% with Silk files and 80.0% with Protaper Universal files used. All predentin was removed when working with Protaper Universal and Silk les. Conclusions: In the histological sections of the root canals treated with K-files, the larger amount of dentine particles and predentin has been revealed than when using machine tools. The largest amount of predentin and dentine were removed with Protaper Universal files. Silk endodontic system is better for treatment of the root canals dentine surface in the apical area compared to Protaper Universal and K-files. | en |
dc.language.iso | en | en |
dc.publisher | Wiadomości Lekarskie | pol |
dc.subject | root canals | en |
dc.subject | endodontic treatment | en |
dc.subject | K-file | en |
dc.subject | protaper universal | en |
dc.subject | silk | en |
dc.title | Comparative quality assessment of root canal preparation with different systems of endodontic instruments | en |
dc.type | Article | en |